home *** CD-ROM | disk | FTP | other *** search
- SECTION 07191
-
- PENETRATING SEALER-PRIMER
- NOTE ** SEAL-KRETE, Inc. Waterproofing Sealer, penetrating
- sealer-primer.
- NOTE **
- NOTE ** This section is based on products manufactured by
- SEAL-KRETE, Inc., located at the following address:
- NOTE ** 306 Gandy Road
- NOTE ** Auburndale, FL 33823- 1527
- NOTE ** Tel: (800) 323-7357
- NOTE ** Tel: (941) 967-1535
- NOTE ** Fax: (941) 965-2326
- NOTE **
- NOTE ** In addition to the product specified in this
- section, SEAL-KRETE, Inc. offers a complete line of
- coating products.
- NOTE **
- NOTE ** SECTION 07191 - PENETRATING SEALER-PRIMER,
- Copyright 1997, The Architect's Catalog, Inc.
-
-
- PART 1 GENERAL
-
- 1.1 SECTION INCLUDES
-
- A. Non-pigmented and pigmented sealer-primer for horizontal
- and vertical surfaces.
-
- B. Concrete dustproofer.
-
- 1.2 RELATED SECTIONS
- NOTE ** Delete any sections below not relevant to this
- project; add others as required.
-
- A. Section 07140 - Fluid Applied Waterproofing.
-
- B. Section 09900 - Paints and Coatings.
-
- 1.3 REFERENCES
- NOTE ** Delete references from the list below that are not
- actually required by the text of the edited
- section.
-
- A. ASTM D 1653 - Standard Test Method for Water Vapor
- Transmission of Organic Coating Films.
-
- B. ASTM E 514 - Standard Test Method for Water Penetration
- and Leakage Through Masonry.
-
- C. FS TT-P-0035 - Paint, Cementitious, Powder, White and
- Colors (For Interior and Exterior Use).
-
- 1.4 SUBMITTALS
-
- A. Submit under provisions of Section 01300.
-
- B. Product Data: Manufacturer's descriptive literature for
- sealer-primer; indicate compliance to specified
- requirements.
-
- C. Quality Control Submittals:
- 1. Manufacturer's instructions: Printed installation
- instructions for each product, including product
- storage requirements.
- 2. Manufacturer's Safety Data Sheets (M.S.D.S.).
-
- D. Closeout Submittals:
- 1. Special warranty documents: Issued and executed
- jointly and individually by Contractor and installer
- of this section.
- 2. Manufacturer's warranty document: Issued and
- executed by manufacturer of sealer-primer.
-
- 1.5 QUALITY ASSURANCE
-
- A. Regulatory Requirements: Products shall comply with
- federal, state, and local volatile organic compounds
- (VOC) regulations.
-
- B. Mock-Ups: Provide sealer-primer material for mock-ups
- specified in affected sections.
- NOTE ** Delete the following paragraph if not required.
-
- C. Pre-Installation Meeting:
- 1. Convene at job site seven (7) calendar days prior to
- scheduled beginning of construction activities of
- this section to review requirements of this section.
- 2. Require attendance by representatives of the
- following:
- a. Sealer-primer manufacturer.
- b. Installer of this section.
- c. Other entities directly affecting, or affected
- by, construction activities of this section.
- 3. Notify Architect four (4) calendar days in advance of
- scheduled meeting date.
-
- 1.6 DELIVERY, STORAGE, AND HANDLING
-
- A. Store products of this section in manufacturer's unopened
- packaging until installation.
-
- B. Maintain storage area conditions for products of this
- section in accordance with manufacturer's instructions
- until installation.
-
- 1.7 PROJECT CONDITIONS
-
- A. Do not apply sealer-primers to surfaces below 50 degrees
- F (10 degrees C) or above 95 degrees F (48 degrees C)
- unless recommended by the manufacturer.
-
- B. Do not apply sealer-primer when rain is predicted within
- 24 hours or less than 1 day after surface has been wet.
-
- C. Do not apply sealer-primer in high or gusty winds.
-
- 1.8 WARRANTY
-
- A. Special warranties: Contractor and installer of this
- section shall jointly and individually warrant sealer-
- primer installation against failure due to incorrect
- application for a period of 5 years from the date of
- Substantial Completion.
-
- B. Manufacturer's warranty: Manufacturer's limited warranty
- against failure of sealer-primer installation due to
- failure of sealer-primer material for a period of 5 years
- from the date of Substantial Completion.
-
-
- PART 2 PRODUCTS
-
- 2.1 MANUFACTURERS
-
- A. Acceptable Manufacturer: SEAL-KRETE, Inc.; 306 Gandy
- Road, Auburndale, FL 33823- 1527. ASD. Tel: (800) 323-
- 7357 or (941) 967-1535, Fax: (941) 965-2326.
- NOTE ** Delete one of the two following paragraphs;
- coordinate with Division 1 requirements.
-
- B. Requests for substitution will be considered in
- accordance with provisions of Section 01600.
-
- C. Substitutions: Not permitted.
-
- 2.2 MATERIALS
-
- A. Sealer-Primer: SEAL-KRETE Waterproofing Sealer.
- 1. Characteristics: Clear, non-staining, waterborne
- acrylic-base penetrating sealer-primer containing no
- VOC's (volatile organic compounds) or petroleum
- distillates.
- 2. Performance requirements:
- a. Resistance to water penetration: Minimum rating
- of Excellent, when tested according to FS TT-P-
- 0035, modified using 4 by 8 by 16 inch (100 by
- 200 by 400 mm) concrete block, at equivalent of
- 98 mph (158 km/h) wind speed.
- NOTE ** Verify actual performance value for the following
- with the manufacturer.
- 3. Resistance to water penetration: No more than
- ____ dampness appearing on back of wall specimen,
- when tested in accordance with ASTM E 514 for 4
- hours.
- a. Comply with Florida Department of Transportation
- Specification 926-16 for Type "O" Compounds,
- Florida DOT Method FM5-518.
- NOTE ** Verify actual performance value for the following
- with the manufacturer.
- b. Water vapor transmission: ____ perms (____
- metric perms), maximum, when tested in accordance
- with ASTM D 1653.
- c. Corrosion resistance: No visible degradation of
- film after 48 hours, when subjected to sodium
- hypochlorite, hydrochloric acid, sodium chloride
- (salt), and chlorine.
- d. Solids content: 10 percent, minimum.
- e. Flammability: Non-flammable.
- f. Toxicity: USDA approved for application to
- surfaces where there is possibility of contact
- with food.
- NOTE ** Verify the actual performance values for the
- following three properties with the manufacturer.
- g. Tensile strength: ___ psi (___ kPa), when tested
- in accordance with _____.
- h. Freeze/thaw stability: ____, when tested in
- accordance with _____.
- i. Mechanical stability: _____, when tested in
- accordance with _____.
- NOTE ** If fading resistance or light stability is
- important, verify method of test with manufacturer.
- Otherwise, delete the following two paragraphs.
- j. Fading resistance: Approximately 0.05 percent,
- maximum, after 312 hours of testing in accordance
- with ______.
- k. Light stability: _____, when tested in
- accordance with _____.
- NOTE ** Retain one of the following two paragraphs if
- pigmentation of sealer is required for project;
- delete both paragraphs if no pigmentation of sealer
- is required for project.
-
- B. Pigmenting Agent: Latex-based paint, specified in
- Section 09900.
-
- C. Pigmenting Agent: Latex-based stain, specified in
- Section 09900.
-
-
- PART 3 EXECUTION
-
- 3.1 EXAMINATION
-
- A. Verify that substrates to receive sealer-primer are in
- accordance with manufacturer's instructions.
-
- 3.2 PREPARATION
-
- A. Protect adjacent surfaces to prevent accidental
- application to surfaces not indicated to receive sealer-
- primer; remove accidental applications from surfaces
- immediately, following manufacturer's instructions.
- NOTE ** Delete the following paragraph if no existing
- surfaces to be coated in project.
-
- B. Preparation of existing surfaces:
- 1. Remove loose or deteriorated materials, including,
- but not limited to, scale, spalling, paint, or other
- coatings.
- 2. Clean with detergent-based materials, as recommended
- by manufacturer's instructions; cleaning with solvent-
- based or oil-based cleaners is prohibited.
-
- 3.3 APPLICATION
-
- A. Apply sealer-primer in accordance with manufacturer's
- instructions for indicated project conditions; for multi-
- coat applications, allow specified curing time between
- subsequent coats.
-
- B. Addition of materials to sealer-primer is prohibited,
- except as recommended by manufacturer.
- NOTE ** Delete the following paragraph if specifying
- pigmented water repellent application only.
-
- C. Apply non-pigmented sealer-primer to the following
- surfaces:
- NOTE ** Retain one or more of the following sub-paragraphs,
- as applicable to project conditions.
- 1. New concrete paving.
- 2. Existing concrete paving.
- 3. New brick paving.
- 4. Existing brick paving.
- 5. New stone paving.
- 6. Existing stone paving.
- 7. New foundation walls as primer for subsequent
- installation of waterproofing specified in Section
- 07140.
- 8. Existing foundation walls as primer for subsequent
- installation of waterproofing specified in Section
- 07140.
- 9. New vertical cast-in-place concrete surfaces.
- 10. Existing vertical cast-in-place concrete surfaces.
- 11. New horizontal cast-in-place concrete surfaces.
- 12. New horizontal cast-in-place concrete surfaces as
- curing compound and sealer.
- 13. New horizontal cast-in-place concrete surfaces as
- single-coat dustproofer.
- 14. Existing horizontal cast-in-place concrete surfaces
- as single-coat dustproofer.
- 15. Existing horizontal cast-in-place concrete surfaces.
- 16. New vertical precast concrete surfaces.
- 17. Existing vertical precast concrete surfaces.
- 18. New horizontal precast concrete surfaces.
- 19. Existing horizontal precast concrete surfaces.
- 20. New tilt-up concrete panel surfaces.
- 21. Existing tilt-up concrete panel surfaces.
- 22. New concrete masonry unit surfaces.
- 23. Existing concrete masonry unit surfaces.
- 24. New brick masonry surfaces.
- 25. Existing brick masonry surfaces.
- 26. New stone masonry surfaces.
- 27. Existing stone masonry surfaces.
- 28. New galvanized metal surfaces.
- 29. Existing galvanized metal surfaces.
- 30. New wood surfaces.
- 31. Existing wood surfaces.
- 32. New concrete roof tile.
- 33. Existing concrete roof tile.
- 34. New clay roof tile.
- 35. Existing clay roof tile.
- 36. New vinyl siding
- 37. Existing vinyl siding
- 38. New stucco surfaces.
- 39. Existing stucco surfaces.
- 40. New plaster surfaces.
- 41. Existing plaster surfaces.
- 42. New adobe surfaces.
- 43. Existing adobe surfaces.
- 44. New drywall surfaces.
- 45. Existing drywall surfaces.
- 46. New ceramic tile grout joints.
- 47. Existing ceramic tile grout joints.
- 48. Substrates to receive wallcoverings.
- NOTE ** Delete the following paragraph if specifying non-
- pigmented water repellent application only.
-
- D. Apply sealer-primer, mixed with specified pigmenting
- agent in accordance with manufacturer's instructions, to
- the following surfaces:
- NOTE ** Retain one or more of the following sub-paragraphs,
- as applicable to project conditions.
- 1. New vertical cast-in-place concrete surfaces.
- 2. Existing vertical cast-in-place concrete surfaces.
- 3. New horizontal cast-in-place concrete surfaces.
- 4. Existing horizontal cast-in-place concrete surfaces.
- 5. New vertical precast concrete surfaces.
- 6. Existing vertical precast concrete surfaces.
- 7. New horizontal precast concrete surfaces.
- 8. Existing horizontal precast concrete surfaces.
- 9. New tilt-up concrete panel surfaces.
- 10. Existing tilt-up concrete panel surfaces.
- 11. New concrete masonry unit surfaces.
- 12. Existing concrete masonry unit surfaces.
- 13. New brick masonry surfaces.
- 14. Existing brick masonry surfaces.
- 15. New stone masonry surfaces.
- 16. Existing stone masonry surfaces.
- 17. New galvanized metal surfaces.
- 18. Existing galvanized metal surfaces.
- 19. New wood surfaces.
- 20. Existing wood surfaces.
- 21. New stucco surfaces.
- 22. Existing stucco surfaces.
- 23. New plaster surfaces.
- 24. Existing plaster surfaces.
- 25. New adobe surfaces.
- 26. Existing adobe surfaces.
- 27. New drywall surfaces.
- 28. Existing drywall surfaces.
- 29. Substrates to receive wallcoverings.
-
-
- END OF SECTION
-