  1.                          SECTION 07191
  2.  
  3.                    PENETRATING SEALER-PRIMER
  4. NOTE ** SEAL-KRETE, Inc. Waterproofing Sealer, penetrating
  5.         sealer-primer.
  6. NOTE **
  7. NOTE ** This section is based on products manufactured by
  8.         SEAL-KRETE, Inc., located at the following address:
  9. NOTE **      306 Gandy Road
  10. NOTE **      Auburndale, FL 33823- 1527
  11. NOTE **      Tel:  (800) 323-7357
  12. NOTE **      Tel:  (941) 967-1535
  13. NOTE **      Fax:  (941) 965-2326
  14. NOTE **
  15. NOTE ** In addition to the product specified in this
  16.         section, SEAL-KRETE, Inc. offers a complete line of
  17.         coating products.
  18. NOTE **
  19. NOTE ** SECTION 07191 - PENETRATING SEALER-PRIMER,
  20.         Copyright 1997, The Architect's Catalog, Inc.
  21.  
  22.  
  23. PART 1  GENERAL
  24.  
  25. 1.1 SECTION INCLUDES
  26.  
  27.     A.  Non-pigmented and pigmented sealer-primer for horizontal
  28.         and vertical surfaces.
  29.  
  30.     B.  Concrete dustproofer.
  31.  
  32. 1.2 RELATED SECTIONS
  33. NOTE ** Delete any sections below not relevant to this
  34.         project; add others as required.
  35.  
  36.     A.  Section 07140 - Fluid Applied Waterproofing.
  37.  
  38.     B.  Section 09900 - Paints and Coatings.
  39.  
  40. 1.3 REFERENCES
  41. NOTE ** Delete references from the list below that are not
  42.         actually required by the text of the edited
  43.         section.
  44.  
  45.     A.  ASTM D 1653 - Standard Test Method for Water Vapor
  46.         Transmission of Organic Coating Films.
  47.  
  48.     B.  ASTM E 514 - Standard Test Method for Water Penetration
  49.         and Leakage Through Masonry.
  50.  
  51.     C.  FS TT-P-0035 - Paint, Cementitious, Powder, White and
  52.         Colors (For Interior and Exterior Use).
  53.  
  54. 1.4 SUBMITTALS
  55.  
  56.     A.  Submit under provisions of Section 01300.
  57.  
  58.     B.  Product Data:  Manufacturer's descriptive literature for
  59.         sealer-primer; indicate compliance to specified
  60.         requirements.
  61.  
  62.     C.  Quality Control Submittals:
  63.         1.  Manufacturer's instructions:  Printed installation
  64.             instructions for each product, including product
  65.             storage requirements.
  66.         2.  Manufacturer's Safety Data Sheets (M.S.D.S.).
  67.  
  68.     D.  Closeout Submittals:
  69.         1.  Special warranty documents:  Issued and executed
  70.             jointly and individually by Contractor and installer
  71.             of this section.
  72.         2.  Manufacturer's warranty document:  Issued and
  73.             executed by manufacturer of sealer-primer.
  74.  
  75. 1.5 QUALITY ASSURANCE
  76.  
  77.     A.  Regulatory Requirements:  Products shall comply with
  78.         federal, state, and local volatile organic compounds
  79.         (VOC) regulations.
  80.  
  81.     B.  Mock-Ups:  Provide sealer-primer material for mock-ups
  82.         specified in affected sections.
  83. NOTE ** Delete the following paragraph if not required.
  84.  
  85.     C.  Pre-Installation Meeting:
  86.         1.  Convene at job site seven (7) calendar days prior to
  87.             scheduled beginning of construction activities of
  88.             this section to review requirements of this section.
  89.         2.  Require attendance by representatives of the
  90.             following:
  91.             a.  Sealer-primer manufacturer.
  92.             b.  Installer of this section.
  93.             c.  Other entities directly affecting, or affected
  94.                 by, construction activities of this section.
  95.         3.  Notify Architect four (4) calendar days in advance of
  96.             scheduled meeting date.
  97.  
  98. 1.6 DELIVERY, STORAGE, AND HANDLING
  99.  
  100.     A.  Store products of this section in manufacturer's unopened
  101.         packaging until installation.
  102.  
  103.     B.  Maintain storage area conditions for products of this
  104.         section in accordance with manufacturer's instructions
  105.         until installation.
  106.  
  107. 1.7 PROJECT CONDITIONS
  108.  
  109.     A.  Do not apply sealer-primers to surfaces below 50 degrees
  110.         F (10 degrees C) or above 95 degrees F (48 degrees C)
  111.         unless recommended by the manufacturer.
  112.  
  113.     B.  Do not apply sealer-primer when rain is predicted within
  114.         24 hours or less than 1 day after surface has been wet.
  115.  
  116.     C.  Do not apply sealer-primer in high or gusty winds.
  117.  
  118. 1.8 WARRANTY
  119.  
  120.     A.  Special warranties:  Contractor and installer of this
  121.         section shall jointly and individually warrant sealer-
  122.         primer installation against failure due to incorrect
  123.         application for a period of 5 years from the date of
  124.         Substantial Completion.
  125.  
  126.     B.  Manufacturer's warranty:  Manufacturer's limited warranty
  127.         against failure of sealer-primer installation due to
  128.         failure of sealer-primer material for a period of 5 years
  129.         from the date of Substantial Completion.
  130.  
  131.  
  132. PART 2  PRODUCTS
  133.  
  134. 2.1 MANUFACTURERS
  135.  
  136.     A.  Acceptable Manufacturer:  SEAL-KRETE, Inc.; 306 Gandy
  137.         Road, Auburndale, FL 33823- 1527. ASD. Tel: (800) 323-
  138.         7357 or (941) 967-1535, Fax: (941) 965-2326.
  139. NOTE ** Delete one of the two following paragraphs;
  140.         coordinate with Division 1 requirements.
  141.  
  142.     B.  Requests for substitution will be considered in
  143.         accordance with provisions of Section 01600.
  144.  
  145.     C.  Substitutions:  Not permitted.
  146.  
  147. 2.2 MATERIALS
  148.  
  149.     A.  Sealer-Primer:  SEAL-KRETE Waterproofing Sealer.
  150.         1.  Characteristics:  Clear, non-staining, waterborne
  151.             acrylic-base penetrating sealer-primer containing no
  152.             VOC's (volatile organic compounds) or petroleum
  153.             distillates.
  154.         2.  Performance requirements:
  155.             a.  Resistance to water penetration:  Minimum rating
  156.                 of Excellent, when tested according to FS TT-P-
  157.                 0035, modified using 4 by 8 by 16 inch (100 by
  158.                 200 by 400 mm) concrete block, at equivalent of
  159.                 98 mph (158 km/h) wind speed.
  160. NOTE ** Verify actual performance value for the following
  161.         with the manufacturer.
  162.             3.  Resistance to water penetration:  No more than
  163.                 ____ dampness appearing on back of wall specimen,
  164.                 when tested in accordance with ASTM E 514 for 4
  165.                 hours.
  166.             a.  Comply with Florida Department of Transportation
  167.                 Specification 926-16 for Type "O" Compounds,
  168.                 Florida DOT Method FM5-518.
  169. NOTE ** Verify actual performance value for the following
  170.         with the manufacturer.
  171.             b.  Water vapor transmission:  ____ perms (____
  172.                 metric perms), maximum, when tested in accordance
  173.                 with ASTM D 1653.
  174.             c.  Corrosion resistance:  No visible degradation of
  175.                 film after 48 hours, when subjected to sodium
  176.                 hypochlorite, hydrochloric acid, sodium chloride
  177.                 (salt), and chlorine.
  178.             d.  Solids content:  10 percent, minimum.
  179.             e.  Flammability:  Non-flammable.
  180.             f.  Toxicity:  USDA approved for application to
  181.                 surfaces where there is possibility of contact
  182.                 with food.
  183. NOTE ** Verify the actual performance values for the
  184.         following three properties with the manufacturer.
  185.             g.  Tensile strength:  ___ psi (___ kPa), when tested
  186.                 in accordance with _____.
  187.             h.  Freeze/thaw stability:  ____, when tested in
  188.                 accordance with _____.
  189.             i.  Mechanical stability:  _____, when tested in
  190.                 accordance with _____.
  191. NOTE ** If fading resistance or light stability is
  192.         important, verify method of test with manufacturer.
  193.         Otherwise, delete the following two paragraphs.
  194.             j.  Fading resistance:  Approximately 0.05 percent,
  195.                 maximum, after 312 hours of testing in accordance
  196.                 with ______.
  197.             k.  Light stability:  _____, when tested in
  198.                 accordance with _____.
  199. NOTE ** Retain one of the following two paragraphs if
  200.         pigmentation of sealer is required for project;
  201.         delete both paragraphs if no pigmentation of sealer
  202.         is required for project.
  203.  
  204.     B.  Pigmenting Agent:  Latex-based paint, specified in
  205.         Section 09900.
  206.  
  207.     C.  Pigmenting Agent:  Latex-based stain, specified in
  208.         Section 09900.
  209.  
  210.  
  211. PART 3  EXECUTION
  212.  
  213. 3.1 EXAMINATION
  214.  
  215.     A.  Verify that substrates to receive sealer-primer are in
  216.         accordance with manufacturer's instructions.
  217.  
  218. 3.2 PREPARATION
  219.  
  220.     A.  Protect adjacent surfaces to prevent accidental
  221.         application to surfaces not indicated to receive sealer-
  222.         primer; remove accidental applications from surfaces
  223.         immediately, following manufacturer's instructions.
  224. NOTE ** Delete the following paragraph if no existing
  225.         surfaces to be coated in project.
  226.  
  227.     B.  Preparation of existing surfaces:
  228.         1.  Remove loose or deteriorated materials, including,
  229.             but not limited to, scale, spalling, paint, or other
  230.             coatings.
  231.         2.  Clean with detergent-based materials, as recommended
  232.             by manufacturer's instructions; cleaning with solvent-
  233.             based or oil-based cleaners is prohibited.
  234.  
  235. 3.3 APPLICATION
  236.  
  237.     A.  Apply sealer-primer in accordance with manufacturer's
  238.         instructions for indicated project conditions; for multi-
  239.         coat applications, allow specified curing time between
  240.         subsequent coats.
  241.  
  242.     B.  Addition of materials to sealer-primer is prohibited,
  243.         except as recommended by manufacturer.
  244. NOTE ** Delete the following paragraph if specifying
  245.         pigmented water repellent application only.
  246.  
  247.     C.  Apply non-pigmented sealer-primer to the following
  248.         surfaces:
  249. NOTE ** Retain one or more of the following sub-paragraphs,
  250.         as applicable to project conditions.
  251.         1.  New concrete paving.
  252.         2.  Existing concrete paving.
  253.         3.  New brick paving.
  254.         4.  Existing brick paving.
  255.         5.  New stone paving.
  256.         6.  Existing stone paving.
  257.         7.  New foundation walls as primer for subsequent
  258.             installation of waterproofing specified in Section
  259.             07140.
  260.         8.  Existing foundation walls as primer for subsequent
  261.             installation of waterproofing specified in Section
  262.             07140.
  263.         9.  New vertical cast-in-place concrete surfaces.
  264.         10. Existing vertical cast-in-place concrete surfaces.
  265.         11. New horizontal cast-in-place concrete surfaces.
  266.         12. New horizontal cast-in-place concrete surfaces as
  267.             curing compound and sealer.
  268.         13. New horizontal cast-in-place concrete surfaces as
  269.             single-coat dustproofer.
  270.         14. Existing horizontal cast-in-place concrete surfaces
  271.             as single-coat dustproofer.
  272.         15. Existing horizontal cast-in-place concrete surfaces.
  273.         16. New vertical precast concrete surfaces.
  274.         17. Existing vertical precast concrete surfaces.
  275.         18. New horizontal precast concrete surfaces.
  276.         19. Existing horizontal precast concrete surfaces.
  277.         20. New tilt-up concrete panel surfaces.
  278.         21. Existing tilt-up concrete panel surfaces.
  279.         22. New concrete masonry unit surfaces.
  280.         23. Existing concrete masonry unit surfaces.
  281.         24. New brick masonry surfaces.
  282.         25. Existing brick masonry surfaces.
  283.         26. New stone masonry surfaces.
  284.         27. Existing stone masonry surfaces.
  285.         28. New galvanized metal surfaces.
  286.         29. Existing galvanized metal surfaces.
  287.         30. New wood surfaces.
  288.         31. Existing wood surfaces.
  289.         32. New concrete roof tile.
  290.         33. Existing concrete roof tile.
  291.         34. New clay roof tile.
  292.         35. Existing clay roof tile.
  293.         36. New vinyl siding
  294.         37. Existing vinyl siding
  295.         38. New stucco surfaces.
  296.         39. Existing stucco surfaces.
  297.         40. New plaster surfaces.
  298.         41. Existing plaster surfaces.
  299.         42. New adobe surfaces.
  300.         43. Existing adobe surfaces.
  301.         44. New drywall surfaces.
  302.         45. Existing drywall surfaces.
  303.         46. New ceramic tile grout joints.
  304.         47. Existing ceramic tile grout joints.
  305.         48. Substrates to receive wallcoverings.
  306. NOTE ** Delete the following paragraph if specifying non-
  307.         pigmented water repellent application only.
  308.  
  309.     D.  Apply sealer-primer, mixed with specified pigmenting
  310.         agent in accordance with manufacturer's instructions, to
  311.         the following surfaces:
  312. NOTE ** Retain one or more of the following sub-paragraphs,
  313.         as applicable to project conditions.
  314.         1.  New vertical cast-in-place concrete surfaces.
  315.         2.  Existing vertical cast-in-place concrete surfaces.
  316.         3.  New horizontal cast-in-place concrete surfaces.
  317.         4.  Existing horizontal cast-in-place concrete surfaces.
  318.         5.  New vertical precast concrete surfaces.
  319.         6.  Existing vertical precast concrete surfaces.
  320.         7.  New horizontal precast concrete surfaces.
  321.         8.  Existing horizontal precast concrete surfaces.
  322.         9.  New tilt-up concrete panel surfaces.
  323.         10. Existing tilt-up concrete panel surfaces.
  324.         11. New concrete masonry unit surfaces.
  325.         12. Existing concrete masonry unit surfaces.
  326.         13. New brick masonry surfaces.
  327.         14. Existing brick masonry surfaces.
  328.         15. New stone masonry surfaces.
  329.         16. Existing stone masonry surfaces.
  330.         17. New galvanized metal surfaces.
  331.         18. Existing galvanized metal surfaces.
  332.         19. New wood surfaces.
  333.         20. Existing wood surfaces.
  334.         21. New stucco surfaces.
  335.         22. Existing stucco surfaces.
  336.         23. New plaster surfaces.
  337.         24. Existing plaster surfaces.
  338.         25. New adobe surfaces.
  339.         26. Existing adobe surfaces.
  340.         27. New drywall surfaces.
  341.         28. Existing drywall surfaces.
  342.         29. Substrates to receive wallcoverings.
  343.  
  344.  
  345.                          END OF SECTION